List of parameters
Parameters
1-133
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: The parameter is used to select a motor from a motor parameter list.
When changing the code number (with the exception to the value 0), all of the motor parameters are pre-assigned
from the internally available parameter lists.
Dependency: Only code numbers for motor types can be selected that correspond to the motor type selected in p0300. For 1PH2,
1PH4, 1PH7, 1PM4, 1PM6, 1FT6 motors, code numbers are also possible, whose fourth decimal position is greater
by a value of 1 or 2 than the matching motor type in p0300. For 1FE1 motors, the third decimal position can be
higher by a value of 1.
Refer to: p0300
Notice: The list for motor codes /encoder codes can be found in the following literature:
SINAMICS S List Manual
Note: The motor code number can only be changed if the matching list motor was first selected in p0300.
For a motor with DRIVE-CLiQ, p0301 cannot be changed. In this case, p0301 is automatically written to the code
number of the motor parameter read-in (r0302) if p0300 is set to 10000.
When selecting a list motor (p0300 >= 100), drive commissioning can only be exited if a code number is selected.
Description: Displays the motor code number from the saved motor data from a motor with DRIVE-CLiQ.
Note: Drive commissioning can only be exited if the code number that was downloaded (r0302) matches the stored code
number (p0301). If the numbers differ, then the motor data set should be re-loaded using p0300 = 10000.
The motor data are always expected from the first encoder that is assigned to the drive data sets (refer to p0187 =
encoder 1) data set number.
Description: Displays the status word of the automatic motor parameter sensing of a motor with DRIVE-CLiQ.
p0301[0...n] Motor code number selection / Mot code No. sel
VECTOR Can be changed: C2(1, 3), U Calculated: - Access level: 1
Data type: Unsigned16 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: FEM Expert list: 1
Min Max Factory setting
0 65535 0
r0302[0...n] Motor code number of motor with DRIVE-CLiQ / Motor code Mot DLQ
SERVO, VECTOR Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r0303[0...n] Motor status word from motor with DRIVE-CLiQ / Motor ZSW Drv-CliQ
SERVO, VECTOR Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Motor data sets Two One -
01 Mot conn type Delta Star -