Parameters
List of parameters
1-104
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Using this parameter, the data set is assigned to a DRIVE-CLiQ Hub Module Cabinet (DMC).
This unique component number is assigned when parameterizing the topology.
Only component numbers of components that operate as hub can be entered into this parameter.
This parameter has two indices, because there are two DRIVE-CLiQ nodes in the DMC20.
[0] = 1. DRIVE-CLiQ node
[1] = 2. DRIVE-CLiQ node
Description: Sets the component number for the Terminal Module.
This unique component number is assigned when parameterizing the topology.
Only component numbers can be entered into this parameter that correspond to a Terminal Module.
Description: Detecting any assigned DRIVE-CLiQ Hub Module Cabinet (DMC).
Description: Detects the Terminal Module assigned to this drive and data set.
Note: While p0154 = 1, the READY LED flashes green/orange or red/orange with 2 Hz at the appropriate Terminal Mod-
ule.
p0151[0...1] DRIVE-CLiQ Hub component number / Hub comp_no
DMC20 Can be changed: C1(4) Calculated: - Access level: 4
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 199 0
p0151 Terminal Module component number / TM comp_no
TM15, TM15DI_DO,
TM17, TM31, TM41,
TM54F_MA,
TM54F_SL
Can be changed: C1(4) Calculated: - Access level: 4
Data type: Unsigned8 Dynamic index: - Func. diagram: 9550, 9552
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 199 0
p0154 DRIVE-CLiQ Hub detection via LED / Hub detection LED
DMC20 Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0
p0154 Terminal Module detection via LED / TM detection LED
TM15, TM15DI_DO,
TM17, TM31, TM41,
TM54F_MA,
TM54F_SL
Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0