Parameters
List of parameters
1-280
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Values: 0: Inactive
1: Starts a parameter reset
100: Starts a BICO interconnection reset
Dependency: Refer to: p0010
Note: A factory setting run can only be started if p0010 was first set to 30 (parameter reset).
At the end of the calculations, p0970 is automatically set to 0.
Description: The parameter is used to initiate that the parameters are reset on Terminal Module 17 (TM17).
Parameter p0151 is not reset. It is only reset if the entire drive unit is reset to the factory settings (p0976).
Values: 0: Inactive
1: Starts a parameter reset
100: Starts a BICO interconnection reset
Dependency: Refer to: p0010
Note: A factory setting run can only be started if p0010 was first set to 30 (parameter reset).
At the end of the calculations, p0970 is automatically set to 0.
Description: The parameter is used to initiate that the parameters are reset on Terminal Module 15 (TM15).
Parameter p0151 is not reset. It is only reset if the entire drive unit is reset to the factory settings (p0976).
Values: 0: Inactive
1: Starts a parameter reset
100: Starts a BICO interconnection reset
Dependency: Refer to: p0010
Note: A factory setting run can only be started if p0010 was first set to 30 (parameter reset).
At the end of the calculations, p0970 is automatically set to 0.
Description: The parameter is used to initiate that the parameters are reset on Terminal Module 15 (TM15).
The sampling time p4099 is not reset if in so doing a conflict occurs with the basic clock cycle.
Parameter p0151 is not reset. It is only reset if the entire drive unit is reset to the factory settings (p0976).
Values: 0: Inactive
1: Starts a parameter reset
100: Starts a BICO interconnection reset
Dependency: Refer to: p0010
p0970 TM17 reset parameter / TM17 par reset
TM17 Can be changed: C2(30) Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Factory settings Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 100 0
p0970 TM15 reset parameter / TM15 par reset
TM15 Can be changed: C2(30) Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Factory settings Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 100 0
p0970 TM15DI/DO reset parameter / TM15D par reset
TM15DI_DO Can be changed: C2(30) Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Factory settings Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 100 0