EasyManua.ls Logo

Siemens SINAMICS S Series - F01011 (N) Download interrupted; F01012 (N) Project conversion error; F01015 Internal software error; A01016 (F) CompactFlash card changed

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of faults and alarms
Faults and Alarms
3-1437
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
F01011 (N) Download interrupted
Drive object: All objects
Reaction: NONE
Acknowledge: IMMEDIATELY
Cause: The project download was interrupted.
- the user prematurely interrupted the project download.
- the communication cable was interrupted (cable breakage, cable withdrawn).
Note:
The response to an interrupted download is the state "first commissioning".
Remedy: - check the communication cable.
- download the project again.
- boot from previously saved files (power-down/power-up or p0976).
Reaction upon N: NONE
Acknowl. upon N: NONE
F01012 (N) Project conversion error
Drive object: SERVO, VECTOR
Reaction: OFF2 (NONE)
Acknowledge: IMMEDIATELY
Cause: When converting the project of an older FW version, a fatal error occurred.
The fault value (r0949) specifies the number of the parameter that caused the error.
Notice:
For fault value 600, the motor temperature monitoring is no longer guaranteed.
Remedy: The parameter specified in fault value (r0949) must be checked.
Notice: For fault value 600 the parameterization of p0600 (motor temperature sensor for monitoring) must be cor-
rected (refer to the function diagram 8016 and parameter description for p0600).
Reaction upon N: NONE
Acknowl. upon N: NONE
F01015 Internal software error
Drive object: All objects
Reaction: OFF2
Acknowledge: POWER ON
Cause: An internal software error has occurred.
Fault value (r0949, interpret decimal):
Only for internal Siemens troubleshooting.
Remedy: - carry out a POWER ON (power off/on) for all components.
- upgrade the firmware release.
- contact the Hotline.
A01016 (F) CompactFlash card changed
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: On the CompactFlash card, at least one file in the directory /SIEMENS/SINAMICS/ has been illegally changed with
respect to that supplied from the factory. No changes are permitted in this directory.
Alarm value (r2124, interpret decimal):
0: Checksum of one file is incorrect.
1: File missing.
2: Too many files.
3: Incorrect firmware version.
4: Incorrect checksum of the back-up file.
See also: r9925 (CompactFlash card file error)

Table of Contents