Siemens SINAMICS S Series - r4740[0...16383] Trace 0 trace buffer signal 0 floating point; Trace 0 trace sig0; r4741[0...16383] Trace 0 trace buffer signal 1 floating point; Trace 0 trace sig1; r4742[0...16383] Trace 0 trace buffer signal 2 floating point; Trace 0 trace sig2; r4743[0...16383] Trace 0 trace buffer signal 3 floating point; Trace 0 trace sig3

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-869
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the trace buffer (record buffer) for trace 0 and signal 0.
The trace (record) buffer is sub-divided into memory banks, each containing 16384 values. Parameter p4795 can
be used to toggle between the individual banks.
Example A:
The first 16384 values of signal 0, trace 0 are to be read-out.
In this case, memory bank 0 is set with p4795 = 0. The first 16384 values can now be read-out using r4740[0] to
r4740[16383].
Example B:
The values 16385 to 32768 from signal 0, trace 0 are to be read-out.
In this case, memory bank 1 is set with p4795 = 1. The values can now be read out in r4740[0] to r4740[16383].
Dependency: Refer to: p4795
Description: Displays the trace buffer (record buffer) for trace 0 and signal 1.
Dependency: Refer to: r4740, p4795
Description: Displays the trace buffer (record buffer) for trace 0 and signal 2.
Dependency: Refer to: r4740, p4795
Description: Displays the trace buffer (record buffer) for trace 0 and signal 3.
Dependency: Refer to: r4740, p4795
r4740[0...16383] Trace 0 trace buffer signal 0 floating point / Trace 0 trace sig0
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - -
r4741[0...16383] Trace 0 trace buffer signal 1 floating point / Trace 0 trace sig1
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - -
r4742[0...16383] Trace 0 trace buffer signal 2 floating point / Trace 0 trace sig2
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - -
r4743[0...16383] Trace 0 trace buffer signal 3 floating point / Trace 0 trace sig3
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - -