SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source to define how values are transferred in the operating mode "direct setpoint input/MDI".
BI: p2649 = 1 signal
Values are continually transferred (refer to parameter under dependency).
BI: p2649 = 0 signal
The values are transferred for BI: p2650 = 0/1 signal.
Dependency: Refer to: p2642, p2643, p2644, p2645, p2648, p2650, p2651, p2652
Caution: For BI: p2649 = 1 signal, the following applies:
Motion starts without any explicit control signal.
Note: p2649 can only be changed for p0922 (p2079) = 999.
Description: Sets the signal source to accept the values for edge-triggered selection (BI: p2649 = 0 signal) in the operating mode
"direct setpoint input/MDI".
BI: p2650 = 0/1 signal and BI: p2649 = 0 signal
Values are accepted, edge-triggered (refer to parameter under dependency).
Dependency: Refer to: p2640, p2641, p2642, p2643, p2644, p2645, p2648, p2649, p2651, p2652, r2684
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: The status signal r2684.12 = 0/1 signal is used for acknowledgement.
The operating mode "direct setpoint input/MDI" can be influenced via the following signals:
- intermediate stop via BI: p2640.
- reject traversing task via BI: p2641.
Description: Sets the signal source for the positive direction selection in the operating mode "direct setpoint input/MDI".
Dependency: Refer to: p2576, p2648, p2649, p2650, p2652, p2653, p2654
Note: The following applies for "setting-up":
- the traversing direction can be entered using this binector input.
- if both directions (p2651, p2652) are selected, then the axis remains stationary (zero speed).
- if both directions (p2561, p2652) are de-selected, then the axis remains stationary (zero speed).
The following applies for "positioning":
Using binector inputs p2651 and p2652, when the modulo correction (BI: p2576 = 1 signal) is activated and for
absolute positioning (BI: p2648 = 1 signal), the traversing direction is specified as follows:
p2649 BI: EPOS direct setpoint input/MDI transfer type selection / MDI trans_type sel
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3620
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p2650 BI: EPOS direct setpoint input/MDI setpoint acceptance edge / MDI setp_accept
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3620
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p2651 BI: EPOS direct setpoint input/MDI direction selection, positive / MDI dir_sel pos
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3620
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0