List of parameters
Parameters
1-153
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the ratio between the total moment of inertia/mass (load + motor) and the intrinsic motor moment of iner-
tia/mass (no load).
Dependency: This means that together with p0341, the rated starting (accelerating time) of the motor is calculated for a vector
drive.
Refer to: p0341, r0345, p1498
Note: SERVO:
p0341 * p0342 + p1498 influence the speed/torque pre-control in sensorless operation.
VECTOR:
The product p0341 * p0342 is taken into account when automatically calculating the speed controller (p0340 = 4).
Description: Sets the ratio between the total force of inertia/mass (load + motor) and the intrinsic motor force of inertia/mass (no
load).
Dependency: This means that together with p0341, the rated starting (accelerating time) of the motor is calculated for a vector
drive.
Refer to: p0341, r0345, p1498
Note: SERVO:
p0341 * p0342 + p1498 influence the velocity/force pre-control in sensorless operation.
VECTOR:
The product p0341 * p0342 is taken into account when automatically calculating the speed controller (p0340 = 4).
Description: Sets the motor weight.
The following applies for vector drives (refer to p0107):
The parameter influences the thermal 3 mass model of the induction motor.
Caution: This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
The parameter is automatically preset for motors from the motor list (p0301).
p0342[0...n] Ratio between the total and motor moment of inertia / Mot MomInert Ratio
SERVO, VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 1700, 5042,
5210, 6030, 6031
P-Group: Motor Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
1.000 10000.000 1.000
p0342[0...n] Ratio between the total and motor force of inertia / Mot MomInert Ratio
SERVO (Lin) Can be changed: C2(3), U, T Calculated: CALC_MOD_ALL Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 1700, 5042,
5210, 6030, 6031
P-Group: Motor Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
1.000 10000.000 1.000
p0344[0...n] Motor weight / Motor weight
SERVO, VECTOR Can be changed: C2(3), T Calculated: CALC_MOD_ALL Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 27_1 Unit selection: p0100
Not for motor type: PEM, REL, FEM Expert list: 1
Min Max Factory setting
0.0 [kg] 50000.0 [kg] 0.0 [kg]