Parameters
List of parameters
1-148
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the rated motor force.
Note: For synchronous motors, r0333 is calculated from p0305, p0316, p0327 and p0328. The result can deviate from the
input in p0312. If p0316 = 0, then r0333 = p0312 is displayed.
Description: Displays the torque constant of the synchronous motor used.
Dependency: Refer to: p0316
Note: This parameter is not used for induction motors (p0300 = 1xx).
For synchronous motors, parameter r0334 = p0316 is displayed. if p0316 = 0, r0334 is calculated from p0305 and
p0312.
Description: Displays the force constant of the synchronous motor used.
Dependency: Refer to: p0316
Note: For synchronous motors, parameter r0334 = p0316 is displayed. if p0316 = 0, r0334 is calculated from p0305 and
p0312.
Description: Sets the motor cooling system used.
Values: 0: Non-ventilated
1: Forced cooling
2: Liquid cooling
4: Non-ventilated and internal fan
5: Forced cooling and internal fan
6: Liquid cooling and internal fan
128: No fan
Dependency: For 1LA5 and 1LA7 motors (refer to p0300), the parameter is pre-set as a function of p0307 and p0311.
r0333[0...n] Rated motor force / Mot F_rated
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 8_4 Unit selection: p0100
Not for motor type: - Expert list: 1
Min Max Factory setting
- [N] - [N] - [N]
r0334[0...n] Motor-torque constant, actual / Mot kT act
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 28_1 Unit selection: p0100
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
- [Nm/A] - [Nm/A] - [Nm/A]
r0334[0...n] Motor force constant, actual / Mot kT act
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: 29_1 Unit selection: p0100
Not for motor type: ASM, REL, FEM Expert list: 1
Min Max Factory setting
- [N/Arms] - [N/Arms] - [N/Arms]
p0335[0...n] Motor cooling type / Motor cooling type
SERVO, VECTOR Can be changed: C2(1, 3), T Calculated: - Access level: 1
Data type: Integer16 Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: PEM, REL, FEM Expert list: 1
Min Max Factory setting
0 128 0