After this, the brake control is started, the system waits for the closing time in p1217 and then the pulses are can-
celed.
Dependency: Refer to: p1215, p1216, p1217, p1226
Notice: For p1145 > 0.0, the setpoint is not equal to zero dependent on the selected value. This can therefore cause the
monitoring time in p1227 to be exceeded. In this case, for a driven motor, the pulses are not canceled.
Note: Standstill (zero speed) is detected if, during the complete monitoring time (p1227), the speed setpoint falls below
the speed threshold (p1226).
For p1227 = 300.000 s, the following applies:
The monitoring is deactivated.
For p1227 = 0.000 s, the following applies:
With OFF1 or OFF3 and a ramp-down time = 0, the pulses are immediately canceled and the motor "coasts" down.
Description: Sets the delay time for pulse cancelation.
After OFF1 or OFF3 and zero speed detection, the system waits for this time to expire and the pulses are then can-
celed.
Dependency: Refer to: p1226, p1227
Note: Standstill (zero speed) is detected if, during the complete delay time (p1228), the speed actual value falls below the
speed threshold (p1226).
Description: Displays the status word for the motor holding brake.
p1228 Pulse cancelation delay time / Pulse canc t_del
SERVO, VECTOR Can be changed: U, T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: 2701, 2704
P-Group: Functions Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.000 [s] 10.000 [s] 0.000 [s]
r1229.1...11 CO/BO: Motor holding brake status word / Brake ZSW
SERVO (Extended
brk), VECTOR
(Extended brk)
Can be changed: - Calculated: - Access level: 2
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Functions Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
01 Command open brake (continuous signal) Yes No 2711
03 Pulse enable, expanded brake control Yes No 2711
04 Brake does not open Yes No 2711
05 Brake does not close Yes No 2711
06 Brake threshold exceeded Yes No 2707
07 Brake threshold fallen below Yes No 2704
08 Brake monitoring time expired Yes No 2704
09 Pulse enable request missing/n_ctrl inhib-
ited
Yes No 2707
10 Brake OR logic operation result Yes No 2707
11 Brake AND logic operation result Yes No 2707