List of parameters
Parameters
1-169
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the actual stator resistance (phase value).
The parameter is influenced by the temperature model and includes the temperature-independent cable resistance.
Dependency: Refer to: p0350, p0352, p0620
Description: Displays the actual rotor/secondary section resistance (phase value).
The parameter is influenced by the temperature model.
Dependency: Refer to: p0354, p0620
Note: This parameter is not used for synchronous motors (p0300 = 2xx).
Description: Selects the encoder from the list of encoder types supported.
Values: 0: No encoder
1001: Resolver 1 speed
1002: Resolver 2 speed
1003: Resolver 3 speed
1004: Resolver 4 speed
2001: 2048, 1 Vpp, A/B C/D R
2002: 2048, 1 Vpp, A/B R
2003: 256, 1 Vpp, A/B R
2004: 400, 1 Vpp, A/B R
2005: 512, 1 Vpp, A/B R
2010: 18000, 1 Vpp, A/B R distance-coded
2051: 2048, 1 Vpp, A/B, EnDat, Multiturn 4096
2052: 32, 1 Vpp, A/B, EnDat, Multiturn 4096
2053: 512, 1 Vpp, A/B, EnDat, Multiturn 4096
2054: 16, 1 Vpp, A/B, EnDat, Multiturn 4096
2055: 2048, 1 Vpp, A/B, EnDat, Singleturn
2081: 2048, 1 Vpp, A/B, SSI, Singleturn
2082: 2048, 1 Vpp, A/B, SSI, Multiturn 4096
2083: 2048, 1 Vpp, A/B, SSI, Singleturn, error bit
2084: 2048, 1 Vpp, A/B, SSI, Multiturn 4096, error bit
2110: 4000 nm, 1 Vpp, A/B R distance-coded
2111: 20000 nm, 1 Vpp, A/B R distance-coded
r0395[0...n] Stator resistance, actual / R_stator active
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 6300, 6730,
6731
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Ohm] - [Ohm] - [Ohm]
r0396[0...n] Rotor resistance, actual / R_rotor active
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: 6730
P-Group: Motor Units group: 16_1 Unit selection: p0349
Not for motor type: PEM, REL, FEM Expert list: 1
Min Max Factory setting
- [Ohm] - [Ohm] - [Ohm]
p0400[0...n] Enc type selection / Enc type selection
SERVO, VECTOR Can be changed: C2(1, 4) Calculated: - Access level: 1
Data type: Integer16 Dynamic index: EDS, p0140 Func. diagram: 1580, 4704
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 10050 0