EasyManua.ls Logo

Siemens SINAMICS S Series - p9907 Topology comparison, comparison stage of the component number; Topo_cmpr comp_no; p9908 Topology comparison, comparison stage of a component; Topo_cmpr 1 comp; p9909 Topology comparison, component replacement; Topo_cmpr replace

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-1043
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Enters the number of the component where the setting of how the actual topology should be compared to the target
topology should be changed.
Dependency: Refer to: p9908
Description: Sets the type of comparison of a component in the target topology with the actual topology.
The comparison is started by setting the required value.
Values: 0: High: Compares the complete electronic rating plate
1: Average: Compares the component type and the Order number
2: Low: Compares the component type
3: Minimum: Compares the component class
99: Topology has different comparison stages
Dependency: Refer to: p9907
Note: The electronic rating plate comprises the following data:
- component type (e.g. "SMC20")
- Order No. (e.g. "6SL3055-0AA0-5BA0")
- manufacturer (e.g. SIEMENS)
- hardware version (e.g. "A")
- Serial No. (e.g. "T-P30050495")
When comparing the topology, the following data is compared in the target and actual topologies:
p9908 = 0: Component type, Order No., Hardware version, Manufacturer, Serial No.
p9908 = 1: Component type, Order No.
p9908 = 2: Component type
p9908 = 3: Component class (e.g. Sensor Module or Motor Module)
Description: For p9909 = 1, the serial number and the hardware version of the new replaced component is automatically trans-
ferred from the actual topology into the target topology and then saved in a non-volatile fashion.
For the components that have been replaced, the electronic type plate must match as far as the following data is
concerned:
- component type (e.g. "SMC20")
- Order No. (e.g. "6SL3055-0AA0-5BA0")
p9907 Topology comparison, comparison stage of the component number /
Topo_cmpr comp_no
CU_CX32, CU_S Can be changed: C1(1) Calculated: - Access level: 3
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 199 0
p9908 Topology comparison, comparison stage of a component / Topo_cmpr 1 comp
CU_CX32, CU_S Can be changed: C1(1) Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 99 0
p9909 Topology comparison, component replacement / Topo_cmpr replace
CU_CX32, CU_S Can be changed: C1(1) Calculated: - Access level: 3
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Topology Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 1

Table of Contents

Related product manuals