List of parameters
Parameters
1-819
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: The simulation of a digital input is selected using p4095.
Refer to: p4095
Note: This parameter is not saved when data is backed-up (p0971, p0977).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the simulation mode for the analog inputs of the Terminal Board 30 (TB30).
Values: 0: No simulation mode for analog input x
1: Simulation mode for analog input x
Index: [0] = AI 0 (X482.1/X482.2)
[1] = AI 1 (X482.3/X482.4)
Dependency: The setpoint for the input voltage is specified via p4098.
Refer to: p4098
Note: This parameter is not saved when data is backed-up (p0971, p0977).
AI: Analog Input
Description: Sets the simulation mode for the analog inputs of terminal module 31 (TM31).
Values: 0: No simulation mode for analog input x
1: Simulation mode for analog input x
Index: [0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
Dependency: The setpoint for the input voltage is specified via p4098.
Refer to: p4098
Note: This parameter is not saved when data is backed-up (p0971, p0977).
AI: Analog Input
Description: Sets the simulation mode for the analog input of terminal module 41 (TM41).
Values: 0: No simulation mode for analog input x
1: Simulation mode for analog input x
Index: [0] = AI 0 (X523.1/X523.2)
21 DI/DO 21 (X522.7) High Low -
22 DI/DO 22 (X522.8) High Low -
23 DI/DO 23 (X522.9) High Low -
p4097[0...1] TB30 analog inputs simulation mode / TB30 AI sim_mode
TB30 Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: - Func. diagram: 9104
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0
p4097[0...1] TM31 analog inputs simulation mode / TM31 AI sim_mode
TM31 Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: - Func. diagram: 9566, 9568
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0
p4097[0...0] TM41 analog input, simulation mode / TM41 AI sim_mode
TM41 Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: - Func. diagram: 9663
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0