Parameters
List of parameters
1-344
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source for an unconditional (immediate) closing of the motor holding brake.
Dependency: Refer to: p1215, p1275
Note: [0]: Signal, immediately close brake, inversion via p1275.0
[1]: Signal, immediately close brake, inversion via p1275.1
[2]: Signal, immediately close brake
[3]: Signal, immediately close brake - refer to the factory setting
These four signals form an OR logic operation.
Description: Sets the signal source for the command "open brake".
Dependency: Refer to: p1215, p1221, r1229, p1277
Description: Sets the threshold value for the command "open brake".
Dependency: Refer to: p1220, r1229, p1277
Description: Sets the signal source for the feedback signal "brake closed".
For motor holding brakes with feedback signal, the signal "brake closed" can be activated using p1275.5 = 1.
Dependency: Refer to: p1223, p1275
Note: 1 signal: Brake closed.
p1219[0...3] BI: Immediately close motor holding brake / Close brake
SERVO (Extended
brk), VECTOR
(Extended brk)
Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 2707
P-Group: Functions Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - [0] 0
[1] 0
[2] 0
[3] 1229.9
p1220 CI: Open motor holding brake, signal source, threshold / Open brake thresh
SERVO (Extended
brk), VECTOR
(Extended brk)
Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dynamic index: - Func. diagram: 2707
P-Group: Functions Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 1
p1221 Open motor holding brake, threshold / Open brake thresh
SERVO (Extended
brk), VECTOR
(Extended brk)
Can be changed: U, T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: 2707
P-Group: Functions Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [%] 200.00 [%] 0.00 [%]
p1222 BI: Motor holding brake feedback signal brake closed / Brake feedb closed
SERVO (Extended
brk), VECTOR
(Extended brk)
Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 2711
P-Group: Functions Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0