Parameters
List of parameters
1-1058
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note: Parameter is being prepared - for this firmware version, the function interface is not supported.
Re value = 0:
No terminal assigned, no static agreement.
Re value = 255:
No terminal assigned, static agreement.
Description: Sets the input terminal for input "Emergency Stop" (operating mode "function interface").
The behavior of this input signal is set in p10021.
Values: 0: Statically active
1: F-DI 0 (X521.2/3/6)
2: F-DI 1 (X521.4/5/7)
3: F-DI 2 (X522.1/2/7)
4: F-DI 3 (X522.3/4/8)
5: F-DI 4 (X522.5/6/9)
6: F-DI 5 (X531.2/3/6)
7: F-DI 6 (X531.4/5/7)
8: F-DI 7 (X532.1/2/7)
9: F-DI 8 (X532.3/4/8)
10: F-DI 9 (X532.5/6/9)
255: Statically inact
Index: [0] = Drive group 1
[1] = Drive group 2
[2] = Drive group 3
[3] = Drive group 4
Dependency: Refer to: p10008, p10021
Note: Parameter is being prepared - for this firmware version, the function interface is not supported.
Re value = 0:
No terminal assigned, "Emergency Stop" statically active.
Re value = 255:
No terminal assigned, no "Emergency Stop" statically active.
Description: Sets the signals for the drive group specific signal "Safe State".
Bit 0 = Power_removed
Bit 1 = SS1_active
Bit 2 = SS2_active
Bit 3 = SOS_active
Bit 4 = SLS_active
Bit 5 = Reserved
Index: [0] = Drive group 1
[1] = Drive group 2
[2] = Drive group 3
p10038[0...3] SI Emergency Stop input terminal / SI Emer Stop DI
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 4
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 255 0
p10039[0...3] SI Safe State signal selection / SI Safe State Sel
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 2856
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0001 bin