List of parameters
Parameters
1-1055
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
5: F-DI 4 (X522.5/6/9)
6: F-DI 5 (X531.2/3/6)
7: F-DI 6 (X531.4/5/7)
8: F-DI 7 (X532.1/2/7)
9: F-DI 8 (X532.3/4/8)
10: F-DI 9 (X532.5/6/9)
255: Statically inact
Index: [0] = Drive group 1
[1] = Drive group 2
[2] = Drive group 3
[3] = Drive group 4
Note: SOS: Safe Operating Stop
Re value = 0:
No terminal assigned, safety function always active.
Re value = 255:
No terminal assigned, safety function always inactive.
Description: Assignment of the input terminals for input SLS (operating mode = control interface)
Description, refer to P10022
Values: 0: Statically active
1: F-DI 0 (X521.2/3/6)
2: F-DI 1 (X521.4/5/7)
3: F-DI 2 (X522.1/2/7)
4: F-DI 3 (X522.3/4/8)
5: F-DI 4 (X522.5/6/9)
6: F-DI 5 (X531.2/3/6)
7: F-DI 6 (X531.4/5/7)
8: F-DI 7 (X532.1/2/7)
9: F-DI 8 (X532.3/4/8)
10: F-DI 9 (X532.5/6/9)
255: Statically inact
Index: [0] = Drive group 1
[1] = Drive group 2
[2] = Drive group 3
[3] = Drive group 4
Note: SLS: Safely-Limited Speed
Re value = 0:
No terminal assigned, safety function always active.
Re value = 255:
No terminal assigned, safety function always inactive.
Description: Sets the input terminal for SLS_Limit bit 0 (operating mode "control interface").
p10026[0...3] SI SLS input terminal / SI SLS DI
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 255 0
p10027[0...3] SI SLS_Limit(1) input terminal / SI SLS_Limit(1) DI
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 255 0