Faults and Alarms
List of faults and alarms
3-1452
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
A01304 (F) Firmware version of DRIVE-CLiQ component is not up-to-date
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: On the CompactFlash card, there is a later firmware version than in the connected DRIVE-CLiQ component.
Alarm value (r2124, interpret decimal):
Component number of the DRIVE-CLiQ component involved.
Remedy: Update the firmware (p7828, p7829 and commissioning software).
Reaction upon F: NONE
Acknowl. upon F: IMMEDIATELY
F01305 Topology: Component number missing
Drive object: All objects
Reaction: NONE
Acknowledge: IMMEDIATELY
Cause: The component number from the topology was not parameterized (p0121 (for power unit, refer to p0107), p0131 (for
servo/vector drives, refer to p0107), p0141, p0151, p0161).
Fault value (r0949, interpret decimal):
The fault value includes the particular data set number.
The fault also occurs if speed encoders were configured (p0187 ... p0189), however, no component numbers exist
for them.
In this case, the fault value includes the drive data set number plus 100 * encoder number (e.g. 3xx, if a component
number was not entered into p0141 for the third encoder (p0189)).
See also: p0121 (Power unit component number), p0131 (Motor component number), p0141 (Encoder interface
(Sensor Module) component number), p0142 (Encoder component number), p0151 (Voltage Sensing Module com-
ponent number), p0161 (Option board, component number), p0186 (Motor Data Sets (MDS) number), p0187
(Encoder 1 encoder data set number), p0188 (Encoder 2 encoder data set number), p0189 (Encoder 3 encoder data
set number)
Remedy: Enter the missing component number or remove the component and restart commissioning.
See also: p0121 (Power unit component number), p0131 (Motor component number), p0141 (Encoder interface
(Sensor Module) component number), p0142 (Encoder component number), p0151 (Voltage Sensing Module com-
ponent number), p0161 (Option board, component number), p0186 (Motor Data Sets (MDS) number), p0187
(Encoder 1 encoder data set number), p0188 (Encoder 2 encoder data set number), p0189 (Encoder 3 encoder data
set number)
A01306 Firmware of the DRIVE-CLiQ component being updated
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: Firmware update is active for at least one DRIVE-CLiQ component.
Alarm value (r2124, interpret decimal):
Component number of the DRIVE-CLiQ component.
Remedy: None necessary.
This alarm automatically disappears after the firmware has been updated.
A01314 Topology: Component must not be present
Drive object: All objects
Reaction: NONE
Acknowledge: NONE
Cause: For a component, "de-activate and not present" is set but this component is still in the topology.
Alarm value (r2124, interpret hexadecimal):
Byte 1: Component number
Byte 2: Component class of the component
Byte 3: Connection number
Note: Component class and connection number are described in F01375.