Parameters
List of parameters
1-276
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: The parameter assigned to the fault code is entered in r0951 under the same index.
Refer to: r0951
Description: This parameter is identical to r0945.
Description: Displays the system runtime in milliseconds when the fault occurred.
Dependency: Refer to: r0945, r0947, r0949, r2109, r2114, r2130, r2133, r2136
Notice: The time comprises r2130 (days) and r0948 (milliseconds).
Note: The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
The structure of the fault buffer and the assignment of the indices is shown in r0945.
Description: Displays additional information about the fault that occurred (as integer number).
Dependency: Refer to: r0945, r0947, r0948, r2109, r2130, r2133, r2136
Note: The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
The structure of the fault buffer and the assignment of the indices is shown in r0945.
Description: Lists parameters assigned to a fault.
Dependency: Refer to: r0946
r0947[0...63] Fault number / Fault number
All objects Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 1750, 8060
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r0948[0...63] Fault time received in milliseconds / t_fault recv ms
All objects Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: 1750, 8060
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [ms] - [ms] - [ms]
r0949[0...63] Fault value / Fault value
All objects Can be changed: - Calculated: - Access level: 3
Data type: Integer32 Dynamic index: - Func. diagram: 1750, 8060
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r0951[0...65534] Fault number list / Fault number list
All objects Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dynamic index: - Func. diagram: 8060
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - -