Description: Sets the configuration for the speed setpoint.
Note: Re bit 01:
The interpolator is only effective for clock-cycle synchronous PROFIBUS operation and when the master receives a
sign of life (STW 2.12 ... STW 2.15).
Description: Sets the configuration for the velocity setpoint.
Note: Re bit 01:
The interpolator is only effective for clock-cycle synchronous PROFIBUS operation and when the master receives a
sign of life (STW 2.12 ... STW 2.15).
Description: Sets the configuration for the incremental encoder emulation.
Note: Re bit 01:
The interpolator is only effective for clock-cycle synchronous PROFIBUS operation and when the master receives a
sign of life (STW 2.12 ... STW 2.15).
p1189[0...n] Speed setpoint configuration / n_ctrl config
SERVO, VECTOR Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: DDS, p0180 Func. diagram: 3080
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0011 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Interpolation ramp-fct gen/speed controller
active
Yes No 3080
01 Interpol. op-loop ctrl /speed controller active Yes No 3080
p1189[0...n] Velocity setpoint configuration / v_ctrl config
SERVO (Lin) Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: DDS, p0180 Func. diagram: 3080
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0011 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Interpolation ramp-fct gen/velocity controller
active
Yes No 3080
01 Interpol. op-loop ctrl /velocity controller
active
Yes No 3080
p1189 Incremental encoder emulation configuration / Enc_emulat config
TM41 Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: - Func. diagram: 9674
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0010 bin
Bit field: Bit Signal name 1 signal 0 signal FP
01 Interpol. op-loop ctrl /speed controller active Yes No 9674