Parameters
List of parameters
1-794
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note: DI/DO: Bidirectional Digital Input/Output
Description: Displays the actual input voltage at the analog inputs of the Terminal Board 30 (TB30).
Index: [0] = AI 0 (X482.1/X482.2)
[1] = AI 1 (X482.3/X482.4)
Note: AI: Analog Input
Description: Displays the actual input voltage in V when set as voltage input.
Displays the actual input current in mA when set as current input and with the load resistor switched-in.
Index: [0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
Dependency: The type of analog input AI x (voltage or current input) is set using p4056.
Refer to: r4056, p4056
Note: AI: Analog Input
Description: Displays the actual input voltage in V.
07 DI/DO 7 (X520.9) I/O with time I/O -
08 DI/DO 8 (X521.2) I/O with time I/O -
09 DI/DO 9 (X521.3) I/O with time I/O -
10 DI/DO 10 (X522.4) I/O with time I/O -
11 DI/DO 11 (X521.5) I/O with time I/O -
12 DI/DO 12 (X521.6) I/O with time I/O -
13 DI/DO 13 (X521.7) I/O with time I/O -
14 DI/DO 14 (X521.8) I/O with time I/O -
15 DI/DO 15 (X521.9) I/O with time I/O -
16 DI/DO 16 (X522.2) I/O with time I/O -
17 DI/DO 17 (X522.3) I/O with time I/O -
18 DI/DO 18 (X522.4) I/O with time I/O -
19 DI/DO 19 (X522.5) I/O with time I/O -
20 DI/DO 20 (X522.6) I/O with time I/O -
21 DI/DO 21 (X522.7) I/O with time I/O -
22 DI/DO 22 (X522.8) I/O with time I/O -
23 DI/DO 23 (X522.9) I/O with time I/O -
r4052[0...1] CO: TB30 analog inputs, actual input voltage / TB30 AI inp_V
TB30 Can be changed: - Calculated: - Access level: 1
Data type: Floating Point Dynamic index: - Func. diagram: 9104
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r4052[0...1] CO: TM31 analog inputs, actual input voltage/current / TM31 AI inp_V/I
TM31 Can be changed: - Calculated: - Access level: 1
Data type: Floating Point Dynamic index: - Func. diagram: 9566, 9568
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r4052[0...0] CO: TB41 analog inputs, actual input voltage / TM41 AI inp_V
TM41 Can be changed: - Calculated: - Access level: 1
Data type: Floating Point Dynamic index: - Func. diagram: 9663
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]