Siemens SINAMICS S Series - r0114[0...9] Pulse frequency, minimum recommended; F_puls min recom; p0115[0...0] Sampling time for supplementary functions; t_sample suppl fct

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-93
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the recommended values (indices 0 and 1) for the minimum pulse frequency (p0113). If the system rejects
a change to p0113 because the value to be used lies outside the permitted value range, then instead, the recom-
mended value from r0114 can be used.
Index: [0] = If only the actual drive is changed
[1] = If all drives connected to the DRIVE-CLiQ line are changed
[2] = 2. possible pulse frequency
[3] = 3. possible pulse frequency
[4] = 4. possible pulse frequency
[5] = 5. possible pulse frequency
[6] = 6. possible pulse frequency
[7] = 7. possible pulse frequency
[8] = 8. possible pulse frequency
[9] = 9. possible pulse frequency
Dependency: Refer to: p0113
Note: After exiting commissioning (p0009 = p0010 = 0), the pulse frequencies calculated from the sampling time p115[0]
are displayed in indices 1 to 9. If additional restrictions do not apply (e.g. due to having selected an output filter),
these can be entered into p1800. The maximum pulse frequency of the power units was already taken into account
in r0114.
A value of 0 kHz does not define a recommended pulse frequency.
Description: Sets the basis sampling time for supplementary functions on this object.
Index: [0] = Basis sampl. time
Description: Sets the sampling times for supplementary functions on this object.
Index: [0] = Basis sampl. time
Note: This parameter only applies for setting the sampling times of possible supplementary functions.
A setting of the sampling times of the inputs/outputs must be set in P4099.
r0114[0...9] Pulse frequency, minimum recommended / F_puls min recom
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [kHz] - [kHz] - [kHz]
p0115[0...0] Sampling time for supplementary functions / t_sample suppl fct
CU_CX32, CU_S Can be changed: C1(3) Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [µs] 16000.00 [µs] 4000.00 [µs]
p0115[0...0] Sampling time for supplementary functions / t_sample suppl fct
TB30, TM15DI_DO,
TM31
Can be changed: C1(3) Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [µs] 16000.00 [µs] 4000.00 [µs]