List of parameters
Parameters
1-863
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Index: [0] = Trace 0
[1] = Trace 1
Dependency: Only effective when p4710 does not equal 1.
Description: Sets the trigger threshold for the trace.
Index: [0] = Trace 0
[1] = Trace 1
Dependency: Only effective when p4710 = 2, 3.
Description: Sets the first trigger threshold for trigger via tolerance band.
Index: [0] = Trace 0
[1] = Trace 1
Dependency: Only effective when p4710 = 4, 5.
Description: Sets the second trigger threshold for trigger via tolerance band
Index: [0] = Trace 0
[1] = Trace 1
Dependency: Only effective when p4710 = 4, 5.
Description: Sets the bit mask for the bit mask trigger.
Index: [0] = Trace 0
[1] = Trace 1
Dependency: Only effective when p4710 = 6.
p4712[0...1] Trace trigger threshold / Trace trig_thresh
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
-340.28235E36 340.28235E36 0.00
p4713[0...1] Trace tolerance band trigger threshold / Trace trig thresh
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
-340.28235E36 340.28235E36 0.00
p4714[0...1] Trace tolerance band trigger threshold / Trace trig thresh
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
-340.28235E36 340.28235E36 0.00
p4715[0...1] Trace bit mask trigger, bit mask / Trace trig mask
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
0 4294967295 0