Siemens SINAMICS S Series - r0830.0...15 CO;BO: Motor changeover, status word; Mot_chngov ZSW; p0831[0...15] BI: Motor changeover, contactor feedback; Mot_chg cont fdbk

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-244
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
This feedback signal (0/1 edge) is required after a motor changeover to enable the pulses.
Dependency: Refer to: p0833
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Displays the status word of the motor changeover.
These signals can be connected to digital outputs to change over the motor.
Dependency: Refer to: p0827
Description: Sets the signal source for the feedback signal of the contactors when changing over motors.
There is a fixed inter-relationship between energizing the contactor and the feedback signal.
Example:
A changeover is to be made between MDS0 (motor 0) and MDS1 (motor 1). The contactors should be switched
using bit 4 (contactor 0) and 5 (contactor 1). The changeover should be made with an interconnection of the feed-
back signal.
Implementation:
MDS0: p0827[0] = 4, interconnect output to switch contactor 0 to r0830.4, p0831[4] = "input, feedback signal, con-
tactor 0"
MDS1: p0827[1] = 5, interconnect output to switch contactor 1 to r0830.5, p0831[5] = "input, feedback signal, con-
tactor 1"
The following sequence applies when changing over from MDS0 to MDS1:
1. The status bit p0830.4 is deleted. When the feedback signal (p0831[4]) is connected, the system waits until the
feedback signal "contactor open" is displayed. If the feedback signal is not connected, then the system waits for the
switch-off interlocking time of 320 ms.
r0830.0...15 CO/BO: Motor changeover, status word / Mot_chngov ZSW
SERVO, VECTOR Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: - Func. diagram: 8575
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Motor selection, bit 0 High Low -
01 Motor selection, bit 1 High Low -
02 Motor selection, bit 2 High Low -
03 Motor selection, bit 3 High Low -
04 Motor selection, bit 4 High Low -
05 Motor selection, bit 5 High Low -
06 Motor selection, bit 6 High Low -
07 Motor selection, bit 7 High Low -
08 Motor selection, bit 8 High Low -
09 Motor selection, bit 9 High Low -
10 Motor selection, bit 10 High Low -
11 Motor selection, bit 11 High Low -
12 Motor selection, bit 12 High Low -
13 Motor selection, bit 13 High Low -
14 Motor selection, bit 14 High Low -
15 Motor selection, bit 15 High Low -
p0831[0...15] BI: Motor changeover, contactor feedback / Mot_chg cont fdbk
SERVO, VECTOR Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 8575
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0