Parameters
List of parameters
1-806
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the actual referred output value of the analog outputs of the Terminal Board 30 (TB30).
Index: [0] = AO 0 (X482.5/X482.6)
[1] = AO 1 (X482.7/X482.8)
Description: Displays the actual referred output value of the analog outputs of terminal module 31 (TM31).
Index: [0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
Description: Sets the smoothing time constant of the 1st order low pass filter for the analog outputs of the Terminal Board 30
(TB30).
Index: [0] = AO 0 (X482.5/X482.6)
[1] = AO 1 (X482.7/X482.8)
Description: Sets the smoothing time constant of the 1st-order low pass filter for the analog outputs of terminal module 31
(TM31).
Index: [0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
r4072[0...1] TB30 analog outputs, output value actually referred / TB30 AO outp_val
TB30 Can be changed: - Calculated: - Access level: 1
Data type: Floating Point Dynamic index: - Func. diagram: 9106
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r4072[0...1] TM31 analog outputs, output value actually referred / TM31 AO outp_val
TM31 Can be changed: - Calculated: - Access level: 1
Data type: Floating Point Dynamic index: - Func. diagram: 9572
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
p4073[0...1] TB30 analog outputs, smoothing time constant / TB30 AO T_smooth
TB30 Can be changed: U, T Calculated: - Access level: 1
Data type: Floating Point Dynamic index: - Func. diagram: 9106
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.0 [ms] 1000.0 [ms] 0.0 [ms]
p4073[0...1] TM31 analog outputs, smoothing time constant / TM31 AO T_smooth
TM31 Can be changed: U, T Calculated: - Access level: 1
Data type: Floating Point Dynamic index: - Func. diagram: 9572
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.0 [ms] 1000.0 [ms] 0.0 [ms]