EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-185 6722 - Field weakening characteristic, Id setpoint (ASM, p0300 = 1)

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Diagrams
Vector control
2-1304
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-185 6722 – Field weakening characteristic, Id setpoint (ASM, p0300 = 1)
- 6722 -
Function diagram
87654321
fp_6722_01_eng.vsd
DO: VECTOR
SINAMICS S
23.03.07 V02.05.00
Vector control - Field weakening characteristic, Id setpoint (ASM, p0300 = 1)
r1583
Flux setpoint, smoothed
I_set T_smooth
p1616
Id_set
calculation
M_set steady-state
p1610[D]
M_suppl_accel
p1611[D]
r1508
M_set before M_suppl
Flux setpoint
calculation
r0067
I_outp max
0,9
1
0
MotMod status (r1751)
MIN
Flux setpoint T_smooth
p1582[D]
< 0.3 s
Efficiency opt
0...100 %
p1580[D](0)
f
y
Field weakening
r0056.8
Magnetization
r1405.4
r0056.4
Mot t_excitation
p0346[D]
1 = Flux setpoint soft starting active
p1401.0
1 = Flux build-up control active
p1401.2
Id current limit
r0063[0]
n_act
Field-weakening
characteristic
Efficiency optimization
[6060.5]
<1> Only for vector control without encoder (SLVC).
<1>
Magnetization control
[6730.3]
[6723.1]
[6640.3] [6723.1]
Flux setpoint T_smth Fs
p1584[D]
Mot T_rotor
r0384
p1570[D]
Flux setpoint
p1570[D]
Refer to [1020.7]
p0115[y] (Motor Modules)
ASM: Induction motor
[6640.1]
U_output max
r0071
Mot I_mag_rated act
r0331[M]
+
+
[4715.6]
[2526.2]
[2526.2]

Table of Contents