EasyManua.ls Logo

Siemens SINAMICS S Series - p4701 Measuring function, control; Meas fct ctrl; p4702 Trace recording channels count; Trace rec_chan; r4705[0...1] Trace status; Trace status

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-861
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Values: 0: Stop measuring function
1: Start measuring function
2: Measuring function, check parameterization
Description: Sets the number of recording channels for trace 1 and trace 2.
Procedure:
- cancel the pulses
- set p0009 to 1
- set p4702 to the requested value
- set p0009 to 0
The drive system is then automatically booted.
Values: 0: 4 recording channels per trace
1: 8 recording channels per trace
Recommend.: For performance reasons, in normal operation, the setting p4702 = 0 should be set (4 recording channels per
trace).
Description: Displays the current status of the trace.
Values: 0: Trace inactive
1: Trace is recording presamples
2: Trace is waiting for trigger event
3: Trace is recording
4: Recording (trace) ended
Index: [0] = Trace 0
[1] = Trace 1
p4701 Measuring function, control / Meas fct ctrl
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
0 2 0
p4702 Trace recording channels count / Trace rec_chan
CU_CX32, CU_S Can be changed: C1(1) Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0
r4705[0...1] Trace status / Trace status
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
0 4 -