List of parameters
Parameters
1-861
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Values: 0: Stop measuring function
1: Start measuring function
2: Measuring function, check parameterization
Description: Sets the number of recording channels for trace 1 and trace 2.
Procedure:
- cancel the pulses
- set p0009 to 1
- set p4702 to the requested value
- set p0009 to 0
The drive system is then automatically booted.
Values: 0: 4 recording channels per trace
1: 8 recording channels per trace
Recommend.: For performance reasons, in normal operation, the setting p4702 = 0 should be set (4 recording channels per
trace).
Description: Displays the current status of the trace.
Values: 0: Trace inactive
1: Trace is recording presamples
2: Trace is waiting for trigger event
3: Trace is recording
4: Recording (trace) ended
Index: [0] = Trace 0
[1] = Trace 1
p4701 Measuring function, control / Meas fct ctrl
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
0 2 0
p4702 Trace recording channels count / Trace rec_chan
CU_CX32, CU_S Can be changed: C1(1) Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0
r4705[0...1] Trace status / Trace status
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
0 4 -