EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-210 8018 - Separately excited synchronous motor (FEM, p0300 = 5)

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Diagrams
Signals and monitoring functions
2-1332
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-210 8018 – Separately excited synchronous motor (FEM, p0300 = 5)
- 8018 -
Function diagram
87654321
fp_8018_01_eng.vsd
DO: VECTOR
SINAMICS S
04.07.07 V02.05.00
Signals and montoring functions - Separately excited synchronous motor (FEM, p0300 = 5)
F07913
"Excitation current outside tolerance"
<1> Only for r1649.2 = 1 (excitation in operation, feedback signal)
<2> Only for vector control (p1300 >= 21) and after magnetization has been completed for a flying restart (r0056.4 = 1).
p0115[3] (4000.00 µs)
<1>
T0
<2>
F07914
"Flux outside tolerance"
0T
0T
0
1
0
1
0
1
0.01...10 000.00 [Arms]
p3208[D] (1.00)
0.00...10.00 [s]
p3209[D] (0.02)
0.1...50.0 [%]
p3205[D] (10.0)
r0068[0]
I_act abs. value
[6714.5]
0.01...10 000.00 [Arms]
p3207[D] (1.00)
0.1...100.0 [%]
p3204[D] (10.0)
0.0...10.0 [s]
p3203[D] (1.0)
0.1...100.0 [%]
p3201[D] (10.0)
0.1...100.0 [%]
p3202[D] (10.0)
0.0...10.0 [s]
p3206[D] (5.0)
r0084[0]
Flux actual value
r1598
Flux setpoint total
[6732.1]
[6725.8]
r1626
I_exc_set
[6727.8]
+
+
[8010.4]
|n_act| < p2161
r2199.0
I_exc_act
[6727.6]
r1641
Zero current
r2199.6
T0
T0
0
1
[2526.6]
[6732.3]
Frequency limit active
r0056.11
Motor stalled
r1408.12
Motor stalled
r2198.7
Motor stalled
r2198.7
[2536.3]
0.000..10.000 [s]
p2178[D] (0.010)
F07902
motor stalled (fault value 2)
F07902
motor stalled (fault value 3)
2 x r0384[M]
[2536.3]
Tsample

Table of Contents

Related product manuals