Siemens SINAMICS S Series - p7036 Infeed par_cct circulating current controller proportional gain; Circ_I Kp; p7036[0...n] Par_circuit circulating current control proportional gain; Circ_I Kp; p7037 Infeed par_cct circulating current control integral time; I_circ Tn; p7037[0...n] Par_circuit circulating current control integral time; I_circ Tn

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-891
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the normalized proportional gain for the circulating current controller.
Note: A value of 100 % corresponds to the basic setting derived from loop control parameters (p3421, p3622).
Description: Sets the proportional gain for the circulating current controller.
The parameter is pre-set to the cable resistance.
Description: Sets the normalized integral time of the circulating current controller.
Note: A value of 100 % corresponds to the basic setting derived from the controller sampling time p0115[0].
The integral component of the controller is de-activated with p7037 = 0.
Description: Sets the integral time of the circulating current controller.
The parameter is referred to the current controller sampling time (p0115[0]).
Dependency: Refer to: p0115
p7036 Infeed par_cct circulating current controller proportional gain / Circ_I Kp
A_INF (Parallel),
S_INF (Parallel)
Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00000 [%] 1000.00000 [%] 100.00000 [%]
p7036[0...n] Par_circuit circulating current control proportional gain / Circ_I Kp
VECTOR (Parallel) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00000 [Ohm] 20.00000 [Ohm] 0.00000 [Ohm]
p7037 Infeed par_cct circulating current control integral time / I_circ Tn
A_INF (Parallel),
S_INF (Parallel)
Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.0 [%] 100000.0 [%] 100.0 [%]
p7037[0...n] Par_circuit circulating current control integral time / I_circ Tn
VECTOR (Parallel) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Modulation Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
2.0 1000.0 4.0