Parameters
List of parameters
1-200
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Trace signal for encoder diagnostics (double word representation). The output signal is selected in p0496.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Description: Trace signal for encoder diagnostics (low component). The output signal is selected in p0496.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Description: Trace signal for encoder diagnostics (high component). The output signal is selected in p0496.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Description: Sets the technology application.
The parameter influences the calculation of open-loop and closed-loop control parameters that is e.g. initiated using
p0578.
Values: 100: Standard drive (SERVO)
101: Feed drive (limit current limitation)
102: Spindle drive (rated current limitation)
Dependency: Refer to: p1520, p1521, p1530, p1531, p2000, p2175, p2177
r0497[0...2] Encoder diagnostic signal double word / Enc diag DW
SERVO, VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r0498[0...2] Encoder diagnostic signal word low / Enc diag word low
SERVO, VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r0499[0...2] Encoder diagnostic signal word high / Enc diag word high
SERVO, VECTOR Can be changed: - Calculated: - Access level: 4
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
p0500 Technology application / Techn application
SERVO Can be changed: C2(1, 5), T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Applications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
100 102 100