EasyManua.ls Logo

Siemens SINAMICS S Series - p4800 Function generator control; FG control; r4805 Function generator status; FG status; r4806 BO: Function generator status signal; FG status signal; p4810 Function generator mode; FG operating mode

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-878
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: The function generator is started with p4800 = 1.
The signal is only generated for a 1 signal of BI: p4819.
Values: 0: Stop function generator
1: Start function generator
2: Check function generator parameterization
Dependency: Refer to: p4819
Description: Displays the actual status of the function generator.
Values: 0: Inactive
1: Generate accelerating ramp to offset
2: Generate parameterized signal shape
3: Generate braking ramp
4: Function generator stopped due to missing enable signals
5: Function generator waits for BI: p4819
6: Function generator parameterization has been checked
Dependency: Refer to: p4800, p4819
Description: Displays the status of the function generator.
0 signal: Function generator inactive
1 signal: Function generator running
Description: Sets the operating mode of the function generator.
p4800 Function generator control / FG control
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 2 0
r4805 Function generator status / FG status
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 6 -
r4806 BO: Function generator status signal / FG status signal
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
p4810 Function generator mode / FG operating mode
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 99 0