Parameters
List of parameters
1-74
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the torque/force generating current setpoint.
Note: This value is irrelevant for the V/f control mode.
Description: Displays the actual value for the active current.
Dependency: Refer to: r0030
Note: The active current actual value is available smoothed (r0030) and unsmoothed (r0078).
Description: Displays the torque-generating current actual value (Iq_act).
Dependency: Refer to: r0030
Note: This value is irrelevant for the V/f control mode.
The torque-generating current actual value is available smoothed (r0030 with 300 ms) and unsmoothed (r0078).
Description: Displays the torque-generating current actual value (Iq_act).
Index: [0] = Unsmoothed
[1] = Smoothed with p0045
Dependency: Refer to: r0030, p0045
Note: These values are irrelevant for the V/f control mode.
The torque-generating current actual value is available smoothed (r0030 with 100 ms, r0078[1] with p0045) and
unsmoothed (r0078[0]).
r0077 CO: Current setpoint force-generating / Iq_set
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1630, 1774,
5714, 6710, 6714, 6719
P-Group: Displays, signals Units group: 6_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r0078 CO: Active current actual value / Iq_act
A_INF, S_INF Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1774, 1775,
8850, 8946, 8950
P-Group: Displays, signals Units group: 6_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r0078 CO: Current actual value, torque-generating / Iq_act
VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1710, 6310,
6714, 6799
P-Group: Displays, signals Units group: 6_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r0078[0...1] CO: Current actual value, torque-generating / Iq_act
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1630, 5714,
5730
P-Group: Displays, signals Units group: 6_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]