Parameters
List of parameters
1-502
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the identified (differential) d-inductance.
Dependency: Refer to: p1909, p1910, r1912, r1913, r1915, r1925, r1927, r1933, r1934, r1935, r1936, r1950, r1951, p1952,
p1953
Note: The Ld characteristic consists of the value pairs from p1932 and p1933 with the same index.
This value corresponds to the value of the total leakage inductance (r0377).
Description: Displays the identification current of the d inductance.
Dependency: Refer to: p1909, p1910, r1912, r1913, r1915, r1925, r1927, r1932, r1934, r1935, r1936, r1950, r1951, p1952,
p1953
Note: The Ld characteristic consists of the value pairs from p1932 and p1933 with the same index.
Description: Displays the identified (differential) q-inductance.
Dependency: Refer to: p1909, p1910, r1932, r1933
Note: The Lq characteristic consists of the value pairs from p1934 and p1935 with the same index.
This value corresponds to the value of the total leakage inductance (r0377).
Description: Displays the identified (differential) q-inductance.
Dependency: Refer to: r1935, p1959, p1960
Note: The Lq characteristic consists of the value pairs from p1934 and p1935 with the same index.
This value corresponds to the value of the total leakage inductance (r0377).
r1932[0...19] d inductance identified / Ld ident
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r1933[0...19] d inductance identification current / Ld I_ident
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r1934[0...9] q inductance identified / Lq ident
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r1934[0...9] q inductance identified / Lq ident
VECTOR (n/M) Can be changed: - Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]