Siemens SINAMICS S Series - p2548 LR cam switching position 2; Cam position 2; p2549 BI: LR enable 1; Enable 1; p2550 BI: LR enable 2; Enable 2; p2551 BI: LR setpoint signal present; Sig s_set pres

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-636
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the cam switching position 2.
Dependency: Refer to: p2547, r2683
Caution: Only after the axis has been referenced can it be guaranteed that the cam switching signals when output have a
"true" position reference.
Note: Position actual value <= cam switching position 2 --> r2683.9 = 1 signal
Position actual value > cam switching position 2 --> r2683.9 = 0 signal
Description: Sets the signal source for enable 1 of the position controller.
Dependency: Refer to: r0899, p2550
Note: The position controller is enabled by ANDing BI: p2549 and BI: p2550.
Description: Sets the signal source for the position controller enable 2.
Dependency: Refer to: p2549
Note: The position controller is enabled by ANDing BI: p2549 and BI: p2550.
When the function module "basic positioner" (r0108.4 = 1) is activated, the following BICO interconnection is estab-
lished: BI: p2550 = 1
Description: Sets the signal source for the "setpoint present" signal.
BI: p2551 = 1 signal:
The end of the positioning operation on the setpoint side is signaled and the positioning and standstill monitoring
activated.
p2548 LR cam switching position 2 / Cam position 2
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed: U, T Calculated: - Access level: 1
Data type: Integer32 Dynamic index: - Func. diagram: 4025
P-Group: Closed loop position control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
-2147483648 [LU] 2147483647 [LU] 0 [LU]
p2549 BI: LR enable 1 / Enable 1
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 4015
P-Group: Closed loop position control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 899.2
p2550 BI: LR enable 2 / Enable 2
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 4015
P-Group: Closed loop position control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p2551 BI: LR setpoint signal present / Sig s_set pres
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 4020
P-Group: Closed loop position control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0