List of parameters
Parameters
1-637
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
BI: p2551 = 0 signal:
The start of a positioning operation or tracking mode on the setpoint side is signaled and the positioning and stand-
still monitoring de-activated.
Dependency: Refer to: p2554, r2683
Note: When the function module "basic positioner" (r0108.4 = 1) is activated, the following BICO interconnection is estab-
lished: BI: p2551 = r2683.2
Description: Sets the signal source for the signal "travel to fixed stop active".
BI: p2552 = 1 signal:
The activity associated with travel to fixed stop is signaled and the detection of the fixed stop is started via the max-
imum following error (p2634).
Dependency: Refer to: r2683
Note: When the function module "basic positioner" (r0108.4 = 1) is activated, the following BICO interconnection is estab-
lished: BI: p2552 = r2683.14
Description: Sets the signal source for the signal "fixed stop reached".
BI: p2553 = 1 signal:
When the fixed stop is reached, this is signaled and the fixed stop monitoring window is activated.
Dependency: Refer to: r2683
Note: When the function module "basic positioner" (r0108.4 = 1) is activated, the following BICO interconnection is estab-
lished: BI: p2553 = r2683.12
Description: Sets the signal source for the signal "traversing command active".
BI: p2554 = 1 signal:
It is signaled that positioning is active and therefore the positioning monitoring is not activated with the signal "set-
point present" (p2551).
Dependency: Refer to: p2551, r2684
Note: When the function module "basic positioner" (r0108.4 = 1) is activated, the following BICO interconnection is estab-
lished: BI: p2554 = r2684.15
p2552 BI: LR signal travel to fixed stop active / Signal TfS act
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 4025
P-Group: Closed loop position control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p2553 BI: LR signal fixed stop reached / Signal fixed stop
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 4025
P-Group: Closed loop position control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p2554 BI: LR signal traversing command active / Sig trav_cmnd act
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 4020
P-Group: Closed loop position control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0