Parameters
List of parameters
1-68
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the line frequency.
Dependency: Refer to: r0024
Note: The line frequency is available smoothed (r0024) and unsmoothed (r0066).
A positive sign of the frequency is obtained when the line supply phases U, V and W are connected with the correct
phase sequence.
A negative sign of the frequency is obtained when the 3 line phases are interchanged therefore designating a neg-
ative direction of the rotating field of the 3-phase line supply voltage.
Description: Displays the Motor Module output frequency.
Dependency: Refer to: r0024
Note: The output frequency is available smoothed (r0024) and unsmoothed (r0066).
Description: Displays the actual permissible absolute line-side current.
Index: [0] = Motor mode
[1] = Regenerative mode
Dependency: The permissible current is the minimum from the maximum converter current (r0209), the parameterized current
limits (p3530 to p3533) as well as the maximum permissible current of line filter (r3534).
Refer to: p3530, p3531, r3534
Description: Displays the maximum output current of the Motor Module.
r0066 CO: Line frequency / f_line
A_INF, S_INF Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 8850, 8864,
8950, 8964
P-Group: Displays, signals Units group: 2_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Hz] - [Hz] - [Hz]
r0066 CO: Output frequency / f_outp
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1690, 5300,
5730, 6310, 6730, 6731, 6799
P-Group: Displays, signals Units group: 2_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Hz] - [Hz] - [Hz]
r0067[0...1] Absolute current value permissible / I_abs val perm
A_INF, S_INF Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: 6_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r0067 Output current, maximum / I_outp max
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5722, 6300,
6640, 6724
P-Group: Displays, signals Units group: 6_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]