EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-133 3635 - Interpolator (r0108.4 = 1)

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Diagrams
Basic positioner (EPOS)
2-1248
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-133 3635 – Interpolator (r0108.4 = 1)
- 3635 -
Function diagram
87654321
fp_3635_01_eng.vsd
DO: SERVO, VECTOR
SINAMICS S
08.05.07 V02.05.00
EPOS - Interpolator (r0108.4 = 1)
p0115[5]
r2665
s_set
r2666
v_set
RD
RU
v_set
V
A
Up
Down
S
V
Interpolator
S
a
[3630.8]
-a
[3630.8]
v
[3630.8]
s
[3630.8]
SET
SET
VALUE
v
s
Modulo corr range
1...2147483647 [LU]
p2576 (360000)
0
10
Pos act/set value
(2521)
p2657
Setpoint availabler2683.2
Axis moves forwards
r2683.4
Axis moves backwards
r2683.5
Software limit switch plus reached
r2683.6 Software limit switch minus reached
r2683.7
Tracking activer2683.0
Axis acceleratingr2684.4
Axis decelerating
r2684.5
Activate correctionr2684.7
r2682
Residual distance
r2667
Backlash value
r2685
Corrective value
Backlash comp
-200000...200000 [LU]
p2583 (0)
A07455 “Maximum velocity limited“
A07473 “Beginning of the traversing range reached“
A07474 “End of the traversing range reached“
A07479 “Software limit switch minus reached“
A07480 “Software limit switch plus reached“
F07481 “Axis position < software limit switch minus
F07482 “Axis position > software limit switch plus“
Calculation,
backlash compensation
Traversing command activer2684.15
s_corr)
F(
[3614.8]
1
CORR.
VALUE
[3645.3]
[3646.3]
[3646.3]
[3646.3]
[3646.3]
[3645.3]
[3645.3]
[3645.3]
[3645.3]
[3645.3]
[4010.2]/p2513
[4010.5]/p2516
[4015.1]/p2530
[4015.1]/p2531
Pos_mode relative
0...1
p2603 (1)
&
p2655
(1)
Sel tracking mode
p2656
(2526.3)
EPOS enable
p2658
(2526.0)
Pos valid feedback
p2577
(0)
Modulo corr act
[3610.4]
[3616.1]
[3620.1]
[3630.1]
[4010.8]
[4010.8]
[4015.8]
Jerk activation via order in
the traversing block mode
Jerk limit
1...100000000 [1000 LU/s
3
]
p2574 (1)
0
1 = Jerk limiting active
r2684.6
10
p2575
(0)
Jerk limit act
&
[3646.3]
[3646.3]

Table of Contents

Related product manuals