Siemens SINAMICS S Series - p1462[0...n] Speed controller integral time adaptation speed lower; n_ctrl Tn n lower; p1462[0...n] Velocity contr. integral act. time adaptation velocity lower; v_ctrl Tn n lower; p1463[0...n] Speed controller Tn adaptation speed, upper scaling; n_ctrl Tn n upper; p1463[0...n] Velocity contr. integral act. time adaptation velocity upper; v_ctrl Tn n upper

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-407
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the integration time of the speed controller before the adaptation speed range (0 ... p1464). This value corre-
sponds to the basic setting of the integral time of the speed controller without adaptation (p1461 = 100 %).
Dependency: Refer to: p1463, p1464, p1465
Description: Sets the integration time of the velocity controller before the adaptation velocity range (0 ... p1464). This value cor-
responds to the basic setting of the integral time of the velocity controller without adaptation (p1461 = 100 %).
Dependency: Refer to: p1463, p1464, p1465
Description: Sets the integral time of the speed controller after the adaptation speed range (> p1465). The entry is made referred
to the integral time for the lower adaptation speed range of the speed controller (% referred to p1462).
Dependency: Refer to: p1462, p1464, p1465
Description: Sets the integral time of the velocity controller after the adaptation velocity range (> p1465). The entry is made
referred to the integral time for the lower adaptation velocity range of the velocity controller (% referred to p1462).
Dependency: Refer to: p1462, p1464, p1465
p1462[0...n] Speed controller integral time adaptation speed lower / n_ctrl Tn n lower
SERVO, VECTOR
(n/M)
Can be changed: U, T Calculated: CALC_MOD_CON Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 1700, 5040,
5042, 6040
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [ms] 100000.00 [ms] 20.00 [ms]
p1462[0...n] Velocity contr. integral act. time adaptation velocity lower / v_ctrl Tn n lower
SERVO (Lin) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5040, 5042
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [ms] 100000.00 [ms] 20.00 [ms]
p1463[0...n] Speed controller Tn adaptation speed, upper scaling / n_ctrl Tn n upper
SERVO Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5050
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.0 [%] 200000.0 [%] 100.0 [%]
p1463[0...n] Velocity contr. integral act. time adaptation velocity upper / v_ctrl Tn n upper
SERVO (Lin) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5050
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.0 [%] 200000.0 [%] 100.0 [%]