EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-131 3625 - Mode control (r0108.4 = 1)

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Diagrams
Basic positioner (EPOS)
2-1246
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-131 3625 – Mode control (r0108.4 = 1)
Direct setpoint input mode
[3620]
- 3625 -
Function diagram
87654321
fp_3625_01_eng.vsd
DO: SERVO, VECTOR
SINAMICS S
07.05.07 V02.05.00
EPOS - Mode control (r0108.4 = 1)
POWER ON
Initial state
“Target position reached“ r2684.10 = 1
“Axis stationary“ r2199.0 = 1
Jog mode
[3610]
r2684.10 = 0
r2199.0 = 0
Ref. point approach mode
[3612]
Traversing block
mode
[3616]
Intermediate
stop r2199.0 = 1
Traversing blocks
active
r2684.10 = 0 / r2199.0 = 0
and 0/1 at r2684.12
Ramp stop
r2684.10 = 0 / r2199.0 = 0
Ramp down the drive
depending on the
deceleration rate of the
traversing block
&
"Intermediate stop"
p2640 = 0
"No intermediate stop"
p2640 = 1
"Jog 1 src" p2589 = 1
"Jog 2 src" p2590 = 1
"Jog 1 src" p2589 = 0
"Jog 2 src" p2590 = 0
Ramp stop
r2684.10 = 0 / r2199.0 = 0
r2669: no change
The drive is ramped down with the
maximum deceleration rate (p2573)
"Reject traversing task"
p2641 = 0
Drive at standstill
p0115[5]
&
"Start referencing" p2595 = 0/1
"Select reference type" p2597 = 0
"Stop referencing"
p2595 = 0
Reference point approach active:
r2684.10/11 = 1, r2199.0 = 1
r2684.10/11 = 0, r2199.0 = 0
Referenced
Reference point approach completed:
"Do not reject traversing task" p2641 = 1
"No intermediate stop" p2640 = 1
"Activate traversing task" p2631 = 0/1
"Activate traversing task"
p2631 = 0/1
"Direct setpoint input" p2647 = 0
Direct setpoint input/MDI active
r2670.15
1
1
&
"Do not reject traversing task" p2641 = 1
"No intermediate stop" p2640 = 1
"MDI selection" p2647 = 1
Intermediate stop
r2199.0 = 1
Traversing blocks active
r2684.10 = 0 / r2199.0 = 0
Flying changeover between
positioning p2653 = 0 and setting-up
p2653 = 1 possible
Ramp stop
r2684.10 = 0 / r2199.0 = 0
The drive is ramped down
depending on the deceleration
rate of the traversing block
"Intermediate
stop" p2640 = 0
"No intermediate stop" p2640 = 1
Drive at standstill
MDI/initial state
no task for MDI active
r2684.10 = 1 / r2199.0 =1
Ramp stop
r2684.10 = 0 / r2199.0 = 0
The drive is ramped down
depend. on the maximum
deceleration (p2573)
"Reject traversing task"
p2641 = 0
Drive at standstill
"Activate traversing task"
(p2649 = 0 and p2650 = 0/1) or
continuous transfer (p2649 = 1 and
signal off CI: p2642 (old <> new ))
"Do not reject traversing task" p2641 = 1
"No intermediate stop" p2640 = 1
Continuous transfer p2649 = 1 and
r2665 <> Signal off CI: p2642
"Activate traversing task" p2649 = 0 and p2650 = 0/1
Traversing task
completed
"Traversing task
completed“
<1> The more points exist at a transition, the higher the priority.
S4: Operation (run) ZSWA.00/01/02/11 = 1, ZSWA.06 = 0 [2610]
1
&
&
&
1
Drive at standstill
<1>
r2669 = 0 hex
r2669 = 1 hex
r2669 = 4 hex
r2669 = 2 hex
Positioning/setting-up, r2669 = 8 hex/10 hex
r2684.15 = 1
r2684.15 = 1

Table of Contents

Related product manuals