Parameters
List of parameters
1-46
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the smoothed actual value of the motor velocity.
Dependency: Refer to: r0063
Note: Smoothing time constant = 100 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The value displayed in r0022 is the smoothed value of r0063.
Description: Displays the smoothed line supply frequency.
Dependency: Refer to: r0066
Note: Smoothing time constant = 300 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The line frequency is available smoothed (r0024) and unsmoothed (r0066).
A positive sign of the frequency is obtained when the line supply phases U, V and W are connected with the correct
phase sequence.
A negative sign of the frequency is obtained when the 3 line phases are interchanged therefore designating a neg-
ative direction of the rotating field of the 3-phase line supply voltage.
Description: Displays the smoothed converter frequency.
Dependency: Refer to: r0066
Note: Smoothing time constant = 100 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The output frequency is available smoothed (r0024) and unsmoothed (r0066).
r0022 Actual velocity smoothed / v_act smooth
SERVO (Lin) Can be changed: - Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: 1580, 1680,
4710, 6799
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [m/min] - [m/min] - [m/min]
r0024 CO: Line supply frequency smoothed / f_line smooth
A_INF, S_INF Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 8850, 8950
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Hz] - [Hz] - [Hz]
r0024 Output frequency smoothed / f_outp smooth
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1690, 5300,
5730, 6799
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Hz] - [Hz] - [Hz]