Parameters
List of parameters
1-506
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the identified voltage constant.
Dependency: Refer to: r1937, r1939, p1959, p1960, r1969
Note: This value corresponds to the voltage constant (p0317).
Description: Displays the identified reluctance torque constant.
Dependency: Refer to: r1937, r1938, p1959, p1960, r1969
Note: This value corresponds to the reluctance torque constant (p0328).
Description: Displays the identified reluctance force constant.
Dependency: Refer to: r1937, r1938, p1959, p1960, r1969
Note: This value corresponds to the reluctance force constant (p0328).
Description: Displays the identified, optimum load angle.
Note: This value corresponds to the optimum load angle (p0327).
r1938 Voltage constant identified / kE ident
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Vrms s/m] - [Vrms s/m] - [Vrms s/m]
r1939 Reluctance torque constant identified / kT_reluct ident
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r1939 Reluctance force constant identified / kT_reluct ident
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r1947 Optimum load angle identified / phi_load ident
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [°] - [°] - [°]