SINAMICS S List Manual (LH1), 07/2007
Dependency: Refer to: r3925
Note: The parameter is a copy of p1909.
Description: Successfully completed component of the last rotating measurement carried out.
Dependency: Refer to: r3925
Note: The parameter is a copy of p1959.
Description: Successfully completed component of the last rotating measurement carried out.
11 De-activate pulse measurement Lq Ld Yes No -
12 De-activate rotor resistance Rr measure-
ment
Yes No -
15 Only measure stator resistance and valve
voltage error
Yes No -
r3928[0...n] Motor data identification determined data (synchronous motor) / MotId determ SM
SERVO Can be changed: - Calculated: CALC_MOD_ALL Access level: 3
Data type: Unsigned32 Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 p350 accepted Yes No -
02 p356 accepted Yes No -
06 p410 accepted Yes No -
07 p431 accepted Yes No -
08 p1952 accepted Yes No -
09 p1953 accepted Yes No -
12 p1715 accepted Yes No -
13 p1717 accepted Yes No -
18 p316 accepted Yes No -
19 p317 accepted Yes No -
20 p327 accepted Yes No -
21 p328 accepted Yes No -
22 p341 accepted Yes No -
23 Torque characteristic parameter accepted Yes No -
r3928[0...n] Motor data identification determined data (synchronous motor) / MotId determ SM
SERVO (Lin) Can be changed: - Calculated: CALC_MOD_ALL Access level: 3
Data type: Unsigned32 Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Motor identification Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 p350 accepted Yes No -
02 p356 accepted Yes No -
06 p410 accepted Yes No -
07 p431 accepted Yes No -
08 p1952 accepted Yes No -
09 p1953 accepted Yes No -
12 p1715 accepted Yes No -
13 p1717 accepted Yes No -
18 p316 accepted Yes No -
19 p317 accepted Yes No -
20 p327 accepted Yes No -
21 p328 accepted Yes No -
22 p341 accepted Yes No -
23 Force characteristic parameter accepted Yes No -