Description: Sets the brake control type (with or without diagnostics evaluation).
Example for brake control with diagnostics evaluation.
- brake control in the Motor Modules in booksize format
- Safe Brake Relay for AC Drive
Example for brake control without diagnostics evaluation.
- Brake Relay for AC Drive
Values: 0: Brake control with diagnostics evaluation
1: Brake control without diagnostics evaluation
Note: If the configuration of the motor holding brake (p1215) is set to "no holding brake present" when booting, then an
automatic identification of the motor holding brake will be carried out. If a brake control is detected without diagnos-
tics evaluation (e.g. Brake Relay for AC Drive), then the parameter is set to "brake control without diagnostics eval-
uation".
It is not permissible to parameterize "brake control without diagnostics evaluation" and also enable "safe brake con-
trol" (p1278 = 1, p9602 = 1, p9802 = 1).
Description: Sets the signal source for the OR/AND logic operation.
Dependency: Refer to: r1229
Note: [0]: OR logic operation, input 1 --> the result is displayed in r1229.10.
[1]: OR logic operation, input 2 --> the result is displayed in r1229.10.
[2]: AND logic operation, input 1 --> the result is displayed in r1229.11.
[3]: AND logic operation, input 2 --> the result is displayed in r1229.11.
Description: Sets the configuration of the controller for the DC link voltage (Vdc controller) in the V/f operating mode.
Values: 0: Inhib Vdc ctrl
1: Enables Vdc_max controller
2: Enables Vdc_min controller (kinetic buffering)
3: Enables Vdc_min controller and Vdc_max controller
4: Activates Vdc_max monitoring
5: Activates Vdc_min monitoring
6: Activates Vdc_min monitoring and Vdc_max monitoring
p1278 Brake control, diagnostics evaluation / Brake diagnostics
SERVO, VECTOR Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Functions Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0
p1279[0...3] BI: Motor holding brake, OR/AND logic operation / Brake OR AND
SERVO (Extended
brk), VECTOR
(Extended brk)
Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 2707
P-Group: Functions Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p1280[0...n] Vdc controller or Vdc monitoring configuration (V/f) / Vdc_ctr config V/f
VECTOR Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: DDS, p0180 Func. diagram: 1690, 6320
P-Group: Functions Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 6 1