EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-142 4704 - Position and temperature sensing, encoders 1... 3

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Encoder evaluation
Function Diagrams
2-1259
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-142 4704 – Position and temperature sensing, encoders 1 ... 3
- 4704 -
Function diagram
87654321
fp_4704_01_eng.vsd
DO: SERVO, VECTOR
SINAMICS S
18.04.07 V02.05.00
Encoder evaluation - Position and speed sensing, encoders 1 … 3
A
B
1 signal period
A
B
1
2
1
2
III
u
p
dn
32 bits
Enco-
ders
Sensor
modules
Control unit
Encoder
Comp_No.
p0142[E]
SMx
Raw position signals
Raw position signals
(only from encoder 1)
To speed
sensing
[4710.1]
Enc
grid division
p0407[E]
Abs enc.
Multiturn
p0421[E]
Enc fine
Gx_XIST2
p0419[E]
Encoder pulse number
(number of signals periods per
track and encoder revolution)
p0408[E]
<1>
Abs enc.
Singleturn
p0423[E]
<3><3> <3><3>
A
B
The encoder data set
changeover is shown
at [8570].
Encoder type selection
0 = No encoder
p0400[E]
2
n
2
n
x2n
Free-running position
counter
-1
1
0
31 n-1
n
0
No. of signal
periods
Fine resolution
(multiplication by
hardware)
r0483[n-1]
Enc Gn_XIST1
[4710.1]
[4735.6]
[4740.6]
Enc
configuration
p0404[E]
<3>
Configuration, absolute value encoder
x2
n
Cyclic absolute
position value
Absolute value
Reference mark position
r0483[n-1]
Enc Gn_XIST2
<2> <7>
<2>
<6>
˽ ҏfrom sensor n
Encoder status bits
to Gn_ZSW
[4730.1]
[8016.1]
To thermal motor monitoring
Error code
Measuring probe position
Measuring probe positions
&
Sequence control
Encoder error
processing
SM characteristics
r0458
Multiplication
by hardware
Enc fine
Gx_XIST1
p0418[E]
Invert position actual value
p0410.1[E]
r0487[n-1]
Enc Gn_STW
<7> The contents of r0483/r2723 are determined by the encoder
status word/control word. Refer to [4720] and [4730].
<8> Interface EnDat or SSI.
<9> Only of significance when the "Position control“ function
module is activated (r0108.3 = 1) and with encoder 1.
Function selection
Bit 0-13Bit 14-15
[4720.4]
[4740.7]
[E]
Encoder control word
<2>
(only for absolute value encoders,
e.g. EQN)
p0979[0...25]
Encoder format acc. to PROFIdrive
F31100...A33905
encoder faults/alarms
Enc rot clearance NM
p0425[E]
1 signal period
sin/cos
Incr
DRIVE CLiQ
For SSI encoders: Absolute position information
Enc
squarewave A/B
p0405[E]
0
2
32
-1
Enc_interface
Comp_No.
p0141[E]
[4735.7]
r0481[n-1]
Enc Gn_ZSW
[4730.5]
Encoder status word
Abs enc.
Meas. Step
p0422[E]
<3>
<5>
<4>
<1> For rotary encoders = pulse number setting.
For resolvers = pole pair number setting.
<2> Assignment of the indices: Index [n-1] --> Encoder n
Index [0] --> Encoder 1
Index [1] --> Encoder 2
Index [2] --> Encoder 3
Dir rev rot field
p1821[D]
-1
0
1
Dir rev rot field
p1821[D]
-1
0
1
0
1
Measuring gearbox,
activate position tracking
p0411.0[E]
p0412[E]
and
p0432[E]/
p0433[E]
[4710.1]
Refer to [1020.7]
PROFIdrive sampling time
<3> For "EnDat encoders", these parameters are read out automatically.
<4> For SIMODRIVE-compatible functions: Set p0418 = 11.
<5> Generating the two's complement.
<6> Gn_XIST1 is a free-running position value.
The external control must process the overflows.
<8>
r2723[n-1]
Load grbx abs_val
Dir rev rot field
p1821[D]
[4010.1]
-1
0
1
0
1
Load gearbox, activate position tracking
p2720.0[D]
p2721[D]
and
p2504[D]/p2505[D]
<9>
<9>
<9>
Encoder n
<7><2>

Table of Contents