EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-238 8932 - Sequencer

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Diagrams
Active Infeed
2-1366
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-238 8932 – Sequencer
- 8932 -
Function diagram
87654321
fp_8932_01_eng.vsd
DO: A_INF
SINAMICS S
28.11.06 V02.05.00
Active Infeed - Sequence control
POWER ON <1>
S1: Power-on inhibit
ZSWAE.6 = 1
ZSWAE.0/1/2 = 0
S2: Ready to power-up
ZSWAE.0 = 1
ZSWAE.1/2/6 = 0
Line contactor is open
Wait for power-on
S5a: Discharge ramp
ZSWAE.0/1/2 = 1
ZSWAE.6 = 0
Ramp-down Vdc via ramp
p3566, then cancel the pulses
S4: Operation
ZSWAE.0/1/2 = 1
ZSWAE.6 = 0
Pulses and controller are enabled
Ramp-up Vdc via the ramp
S3a: Close the
line contactor
(refer to [8934] )
Pre-charging
Time monitoring, refer to [8964.7]
&
"0 = OFF1"
(STWAE.0)
"0 = OFF1" (STWAE.0)
&
"Enable operation"
(STWAE.3)
&
&
&
"0 = OFF1"
(STWAE.0)
"0 = OFF2"
(STWAE.1)
&
"0 = OFF2" (STWAE.1)
<1> POWER ON = 24 V electronics power supply OFF --> ON or RESET button.
p0857...p0862, p3490...p3491
Missing
enable signals
[8934]
r3402
&
24 V at EP terminals
power unit
"0 = OFF2" (STWAE.1)
"0 = OFF1" (STWAE.0)
"Commiss. completed"
(p10 = 0 and p9 = 0)
T
p0862
S3: Ready
ZSWAE.0/1 = 1
ZSWAE.2/6 = 0
Line contactor is closed
"0 = OFF2" (STWAE.1)
"Commissioning" (p10 0 or p9 0)
0 V at EP terminals power unit
&
"Commissioning" (p10 0 and p9 0)
"0 = OFF2" (STWAE.1)
0 V at EP terminals, power unit
S7:
Open the line contactor
S6:
Open the line contactor
"Enable operation" (STWAE.3)
"0 = OFF1" (STWAE.0)
T
Closed-loop control operation
r0863.0 [2610.1]
to SERVO/VECTOR
&
"0 = OFF1"
(STWAE.0)
"0= OFF1"
(STWAE.0)
"Enable operation" (STWAE.3)
0 V at EP terminals
power unit
1
p3490
1
1
T
p3490
&
Faults/alarms
F06000
F07220
F07300
A06602
<2> STWAE.xx = Control word, sequence control, infeed bit xx
ZSWAE.xx = Status word, sequence control, infeed bit xx
<2>
<2>
<2>
<2>
<2>
<2>
<2>
<2>
<2>
<2>
<2>
<2>
<2>
<2>
<2>
<2>
<2>
<2>
<2>
0
0
0
p0115[3] (2000.00 µs)
Energize contactor
r0863.1
[8964.6]

Table of Contents