Parameters
List of parameters
1-752
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the v coordinate of the 10th value pair of the friction characteristic.
Dependency: Refer to: p3839, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 1st value pair of the friction characteristic.
Dependency: Refer to: p3820, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the F coordinate of the 1st value pair of the friction characteristic.
Dependency: Refer to: p3820, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 2nd value pair of the friction characteristic.
Dependency: Refer to: p3821, p3845
p3829[0...n] Friction characteristic, value v9 / Friction v9
SERVO (Lin) Can be changed: T Calculated:
CALC_MOD_LIM_REF
Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 4_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [m/min] 21000.00 [m/min] 300.00 [m/min]
p3830[0...n] Friction characteristic, value M0 / Friction M0
SERVO, VECTOR
(n/M)
Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [Nm] 1000000.00 [Nm] 0.00 [Nm]
p3830[0...n] Friction characteristic, value F0 / Friction F0
SERVO (Lin) Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 8_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [N] 1000000.00 [N] 0.00 [N]
p3831[0...n] Friction characteristic, value M1 / Friction M1
SERVO, VECTOR
(n/M)
Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [Nm] 1000000.00 [Nm] 0.00 [Nm]