Parameters
List of parameters
1-48
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
The signal is not suitable as process quantity and may only be used as display quantity.
The DC link voltage is available smoothed (r0026) and unsmoothed (r0070).
Description: Displays the smoothed actual value of the DC link voltage.
Dependency: Refer to: r0070
Notice: For SINAMICS S120 AC Drive (AC/AC) the following applies:
When measuring a DC link voltage < 200 V, for the Power Module (e.g. PM340) a valid measured value is not sup-
plied. In this case, when an external 24V power supply is connected, a value of approx. 24 V is displayed in the dis-
play parameter.
Note: SERVO, VECTOR: Smoothing time constant = 100 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The DC link voltage is available smoothed (r0026) and unsmoothed (r0070).
Description: Displays the smoothed absolute actual current value.
Dependency: Refer to: r0068
Notice: This smoothed signal is not suitable for diagnostics or evaluation of dynamic operations. In this case, the
unsmoothed value should be used.
Note: A_INF, S_INF, VECTOR: Smoothing time constant = 300 ms
SERVO: Smoothing time constant = 100 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The absolute current actual value is available smoothed (r0027) and unsmoothed (r0068).
Description: Displays the smoothed absolute actual current value.
Dependency: Refer to: r0068
Notice: This smoothed signal is not suitable for diagnostics or evaluation of dynamic operations. In this case, the
unsmoothed value should be used.
Note: Smoothing time constant = 300 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The absolute current actual value is available smoothed (r0027) and unsmoothed (r0068).
r0026 CO: DC link voltage smoothed / Vdc smooth
SERVO, VECTOR Can be changed: - Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: 5730, 8750,
8850, 8950
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r0027 CO: Absolute actual current smoothed / I_act abs val smth
A_INF, SERVO,
S_INF, VECTOR
Can be changed: - Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: 5730, 6799,
8850, 8950
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]
r0027 CO: Absolute actual current smoothed / I_act abs val smth
B_INF Can be changed: - Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: 8750
P-Group: Displays, signals Units group: 6_4 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]