Parameters
List of parameters
1-882
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the ramp-up time to the offset for the function generator.
Description: Sets the lower limit for the function generator.
Dependency: For p4810 = 2 the limit only applies to the current setpoint, but not the speed setpoint (offset).
Description: Sets the upper limit for the function generator.
Dependency: For p4810 = 2 the limit only applies to the current setpoint, but not the speed setpoint (offset).
Description: Sets the time slice cycle in which the function generator is called.
Description: Sets the scaling for the amplitude of the signal waveforms for all output channels.
The value can be changed while the function generator is running.
p4827 Function generator ramp-up time to offset / FG ramp-up offset
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [ms] 100000.00 [ms] 32.00 [ms]
p4828 Function generator lower limit / FG lower limit
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
-10000.00 [%] 0.00 [%] -100.00 [%]
p4829 Function generator upper limit / FG upper limit
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [%] 10000.00 [%] 100.00 [%]
p4830 Function generator time slice cycle / FG time slice
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.03125 [ms] 2.00000 [ms] 0.12500 [ms]
p4831 Function generator amplitude scaling / FG amplitude scal
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00000 [%] 200.00000 [%] 100.00000 [%]