EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-135 3645 - Status word 1 (r0108.3 = 1, r0108.4 = 1)

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Diagrams
Basic positioner (EPOS)
2-1250
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-135 3645 – Status word 1 (r0108.3 = 1, r0108.4 = 1)
- 3645 -
Function diagram
87654321
fp_3645_01_eng.vsd
DO: SERVO, VECTOR
SINAMICS S
08.05.07 V02.05.00
EPOS - Status word 1 (r0108.3 = 1, r0108.4 = 1)
11
15
r2683
PosZSW1
Bit No.
10
9
8
7
6
5
4
3
0
1
2
From interpolator [3635.7]
From traversing range limits [3630.7]
From interpolator [3635.7]
From interpolator [3635.7]
From interpolator [3635.7]
From interpolator [3635.7]
From “traversing block“ mode [3616.7]
p0115[4]
r2683.0
r2683.1
r2683.4
r2683.5
r2683.11
r2683.2
r2683.6
r2683.9
1 = Velocity limiting active
1 = Tracking mode active
Status word, positioning mode 1
1 = Setpoint static
Reserved
1 = Axis moves forwards
1 = Axis moves backwards
1 = Software limit switch minus reached
1 = Software limit switch plus reached
1 = Position actual value <= cam switching position 1
1 = Position actual value <= cam switching position 2
1 = Direct output 1 via the traversing block
1 = Direct output 2 via the traversing block
Reserved
r2683.7
r2683.8
r2683.10
From interpolator [3635.7]
From dynamic following error monitoring, cam controllers [4025.8]
From “traversing block“ mode [3616.7]
[4020.1]/p2551
From dynamic following error monitoring, cam controllers [4025.8]
12
13
14
r2683.121 = Fixed stop reached
1 = Fixed stop, clamping torque reached
1 = Travel to fixed stop active
r2683.13
r2683.14
[4025.1]/p2553
[4025.6]/p2552
From “traversing block“ mode [3616.7]
From “traversing block“ mode [3616.7]
From “traversing block“ mode [3616.7]
[4020.1]

Table of Contents