Description: Sets the simulation mode for the digital inputs of terminal module 41 (TM41).
Dependency: The setpoint for the input signals is specified using p4096.
Refer to: p4096
Note: This parameter is not saved when data is backed-up (p0971, p0977).
DI: Digital input
DI/DO: Bidirectional Digital Input/Output
Description: Sets the simulation mode for the digital inputs of terminal module 15 (TM15).
p4095 TM41 digital inputs, simulation mode / TM41 DI sim_mode
TM41 Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X522.1) Simulation Terminal eval. 9660
01 DI 1 (X522.2) Simulation Terminal eval. 9660
02 DI 2 (X522.3) Simulation Terminal eval. 9660
03 DI 3 (X522.4) Simulation Terminal eval. 9660
08 DI/DO 0 (X521.1) Simulation Terminal eval. 9661
09 DI/DO 1 (X521.2) Simulation Terminal eval. 9661
10 DI/DO 2 (X521.3) Simulation Terminal eval. 9662
11 DI/DO 3 (X521.4) Simulation Terminal eval. 9662
p4095 TM15DI/DO digital inputs, simulation mode / TM15D DI sim_mode
TM15DI_DO Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 Dynamic index: - Func. diagram: 9400, 9401,
9402
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI/DO 0 (X520.2) Simulation Terminal eval. -
01 DI/DO 1 (X520.3) Simulation Terminal eval. -
02 DI/DO 2 (X520.4) Simulation Terminal eval. -
03 DI/DO 3 (X520.5) Simulation Terminal eval. -
04 DI/DO 4 (X520.6) Simulation Terminal eval. -
05 DI/DO 5 (X520.7) Simulation Terminal eval. -
06 DI/DO 6 (X520.8) Simulation Terminal eval. -
07 DI/DO 7 (X520.9) Simulation Terminal eval. -
08 DI/DO 8 (X521.2) Simulation Terminal eval. -
09 DI/DO 9 (X521.3) Simulation Terminal eval. -
10 DI/DO 10 (X521.4) Simulation Terminal eval. -
11 DI/DO 11 (X521.5) Simulation Terminal eval. -
12 DI/DO 12 (X521.6) Simulation Terminal eval. -
13 DI/DO 13 (X521.7) Simulation Terminal eval. -
14 DI/DO 14 (X521.8) Simulation Terminal eval. -
15 DI/DO 15 (X521.9) Simulation Terminal eval. -
16 DI/DO 16 (X522.2) Simulation Terminal eval. -
17 DI/DO 17 (X522.3) Simulation Terminal eval. -
18 DI/DO 18 (X522.4) Simulation Terminal eval. -
19 DI/DO 19 (X522.5) Simulation Terminal eval. -
20 DI/DO 20 (X522.6) Simulation Terminal eval. -