EasyManua.ls Logo

Siemens SINAMICS S Series - p0810 BI: Command Data Set selection CDS bit 0; CDS select., bit 0; p0811 BI: Command data set selection CDS bit 1; CDS select., bit 1; p0819[0...2] Copy Drive Data Set DDS; Copy DDS

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-241
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source to select the Command Data Set bit 0 (CDS bit 0).
Dependency: Refer to: r0050, p0811, r0836
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: For a command data set, selected using the binector inputs, is displayed in r0836.
The currently effective command data set is displayed in r0050.
A command data set can be copied using p0809.
Description: Sets the signal source to select the Command Data Set bit 1 (CDS bit 1).
Dependency: Refer to: r0050, p0810, r0836
Note: For a command data set, selected using the binector inputs, is displayed in r0836.
The currently effective command data set is displayed in r0050.
A command data set can be copied using p0809.
Description: Copies a Drive Data Set (DDS) into another.
Index: [0] = Source drive data set
[1] = Target drive data set
[2] = Start copying
Note: Procedure:
1. In Index 0, enter which drive data set is to be copied.
2. In Index 1, enter the drive data set data that is to be copied into.
3. Start copying: Set index 2 from 0 to 1.
p0819[2] is automatically set to 0 when copying is completed.
p0810 BI: Command Data Set selection CDS bit 0 / CDS select., bit 0
SERVO, VECTOR Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 8560
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p0811 BI: Command data set selection CDS bit 1 / CDS select., bit 1
VECTOR Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 8560
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0
p0819[0...2] Copy Drive Data Set DDS / Copy DDS
SERVO, TM41, VEC-
TOR
Can be changed: C2(15) Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: 8565
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 31 0