List of parameters
Parameters
1-837
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the time to set and reset for digital output 12 of terminal module 17 (TM17).
The two times are specified as 16 bit values with a resolution of 0.25 µs.
Note: DO: Digital Output
Description: Displays the time to set and reset for digital output 12 of terminal module 15 (TM15).
The two times are specified as 8 bit values with a resolution of 64 µs.
Note: DO: Digital Output
Description: Displays the time to set and reset for digital output 13 of terminal module 17 (TM17).
The two times are specified as 16 bit values with a resolution of 0.25 µs.
Note: DO: Digital Output
Description: Displays the time to set and reset for digital output 13 of terminal module 15 (TM15).
The two times are specified as 8 bit values with a resolution of 64 µs.
Note: DO: Digital Output
r4262 TM17 set/reset time digital output 12 / TM17 t_set DO 12
TM17 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r4262 TM15 set/reset time digital output 12 / TM15 t_set DO 12
TM15 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r4263 TM17 set/reset time digital output 13 / TM17 t_set DO 13
TM17 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r4263 TM15 set/reset time digital output 13 / TM15 t_set DO 13
TM15 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -